1.
J Prosthet Dent ; 2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37612193

RESUMO

STATEMENT OF PROBLEM: The accuracy of virtual interocclusal records has been evaluated, but clinical studies comparing the clinical output to the virtual design are lacking. PURPOSE: The purpose of this clinical study was to evaluate the agreement between the virtual occlusal scheme designed by a computer-aided design and computer-aided manufacturing software program and the occlusal scheme obtained clinically on the definitive prosthesis assessed with articulating paper. MATERIAL AND METHODS: The virtual occlusal scheme design of 20 single monolithic crowns and their adjacent teeth was obtained by using an intraoral scanning system in 17 participants. These registrations were compared with conventional occlusal records obtained by applying articulating paper in 2 stages: first with 200-µm blue film and the second with 12-µm metallic red articulation tape. The analysis included both the quantity and the quality of the contacts of the conventional occlusal records referred to as the standard method. For accuracy analysis, virtual record sensitivity was calculated per crown as the percentage of true positive virtual contacts of the actual contacts identified by articulating paper. Specificity was also calculated as the percentage of true negative virtual contacts of the actual sites of clearance. RESULTS: The virtual record sensitivity was 98.5 (95% confidence interval [CI] 96-100) for the crowns and 95 (95% CI 85-100) for the adjacent teeth. The virtual record specificity was 88.6 (95% CI 82.4-94.8) for the crowns and 82.6 (95% CI 77.5-87.6) for the adjacent teeth. The agreement between the clinical and virtual contact intensities on the crowns was 83 (95% CI 73-93) and 67.3 (95% CI 56-78.7) for the adjacent teeth. The positive predictive value was 72.83 (95% CI 60-86). The negative predictive value was 100% (95% CI 100-100). CONCLUSIONS: The intraoral scanning system provided clinically sufficient sensitivity and specificity for identifying the occlusal surface contacts of monolithic crowns. A slight decrease was detected in the system's sensitivity and specificity in identifying contacts on adjacent teeth and a larger decrease identifying the intensity of these contacts.

2.
J Funct Biomater ; 14(3)2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36976096

RESUMO

A wide variety of titanium (Ti) alloy dental implant systems are available and as a result, choosing the correct system has become a challenge. Cleanliness of the dental implant surface affects osseointegration but surface cleanliness may be jeopardized during manufacturing. The purpose of this study was to assess the cleanliness of three implant systems. Fifteen implants per system were examined with scanning electron microscopy to identify and count foreign particles. Particle chemical composition analysis was performed with energy-dispersive X-ray spectroscopy. Particles were categorized according to size and location. Particles on the outer and inner threads were quantitatively compared. A second scan was performed after exposing the implants to room air for 10 min. Carbon, among other elements, was found on the surface of all implant groups. Zimmer Biomet dental implants had higher particle numbers than other brands. Cortex and Keystone dental implants showed similar distribution patterns. The outer surface had higher particle numbers. Cortex dental implants were the cleanest. The change in particle numbers after exposure was not significant (p > 0.05). Conclusion: Most of the implants studied were contaminated. Particle distribution patterns vary with the manufacturer. The wider and outer areas of the implant have a higher probability of contamination.

3.
Materials (Basel) ; 16(5)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36903172

RESUMO

BACKGROUND: The purpose of the study was to evaluate the changes of light reflection% on two materials (monolithic zirconia and lithium disilicate) after using two external staining kits following by thermocycling. METHODS: Specimens were sectioned from monolithic zirconia (n = 60) and lithium disilicate (n = 60) then divided into six groups (n = 20). Two different types of external staining kits were used and applied to the specimens. The light reflection% was measured before staining, after staining and after thermocycling using a spectrophotometer. RESULTS: The light reflection% of zirconia was significantly higher compared to lithium disilicate at the beginning of the study (p = 0.005), after staining with kit 1 (p = 0.005) and kit 2 (p = 0.005) and after thermocycling (p = 0.005). For both materials, the light reflection% was lower after staining with Kit 1 compared to kit 2 (p < 0.043). After thermocycling, the light reflection% of lithium disilicate increased (p = 0.027) and was unchanged with Zirconia (p = 0.527). CONCLUSIONS: There is a difference between the materials regarding light reflection% as the monolithic zirconia showed higher light reflection% comparing lithium disilicate throughout the entire experiment. For lithium disilicate, we recommend using kit 1 as we found that, after thermocycling, the light reflection% of kit 2 was increased.

4.
Korean J Orthod ; 53(1): 45-53, 2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36597666

RESUMO

Objective: This study aimed to evaluate the shear bond strength (SBS) of orthodontic brackets bonded to three-dimensionally (3D)-printed materials after various surface treatments and artificial aging compared with that bonded to computer-aided design/computer-aided manufacturing (CAD-CAM) polymethyl methacrylate (PMMA)-milled materials. Methods: Eighty cylindrical specimens were 3D printed and divided into the following four subgroups (n = 20 each) according to the surface treatment and artificial aging procedure. Group A, sandblasted with 50 µm aluminum oxide particles (SA) and aging; group B, sandblasted with 30 µm silica-coated alumina particles (CO) and aging; group C, SA without aging; and group D, CO without aging. For the control group, 20 CAD-CAM PMMA-milled cylindrical specimens were sandblasted with SA and aged. The SBS was measured using a universal testing machine (0.25 mm/min), examined at ×2.5 magnification for failure mode classification, and statistically analyzed (p = 0.05). Results: The retention obtained with the 3D-printed materials (groups A-D) was higher than that obtained with the PMMA-milled materials (control group). However, no significant difference was found between the study and control groups, except for group C (SA without aging), which showed significantly higher retention than the control group (PMMA-SA and thermocycling) (p = 0.037). Study groups A-D predominantly exhibited a cohesive specimen mode, indicating specimen fracture. Conclusions: Orthodontic brackets bonded to 3D-printed materials exhibit acceptable bonding strengths. However, 3D-printed materials are prone to cohesive failure, which may result in crown fractures.

5.
Int J Comput Dent ; 26(3): 211-216, 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36625371

RESUMO

AIM: To evaluate CAD/CAM milling vibrations related to zirconia disk design, framework, and location of digital crown nesting during zirconia soft milling. MATERIALS AND METHODS: In the present in vitro study, 25 round zirconia disks of 98 mm (R group) and 15 D-shaped zirconia disks of 71 mm (D group) were placed in a 5-axis CAD/CAM milling unit. The R group had 3 crown milling sites (n = 75) and the D group had 2 crown milling sites (n = 30). In the R group, site A was located 57 mm, site B was 92 mm, and site C was 123 mm from the machine holder attachment. In the D group, site A was 57 mm and site C was 123 mm from the machine holder attachment. A vibration meter (VB-8200; Lutron) was connected to the disk holder, and data (mm/second) were collected during the milling process at the different nesting locations. One-way ANOVA with post-hoc tests and Bonferroni correction for multiple tests were used to compare the groups (α = 0.05). RESULTS: In the R group, site C exhibited the highest mean vibration values compared with site A (P = 0.001). The first and second cutting tools (2.5 and 1 mm) exhibited statistically significant differences between the D and R groups at milling sites A and C (P < 0.001 and P = 0.003, respectively). CONCLUSIONS: Milling vibration increased as the distance between the machine holder arm and a digitally nested site increased. Round zirconia disks induced higher vibration values compared with D-shaped disks.


Assuntos
Planejamento de Prótese Dentária , Vibração , Humanos , Adaptação Marginal Dentária , Coroas , Desenho Assistido por Computador , Zircônio
6.
Materials (Basel) ; 15(21)2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36363236

RESUMO

The effects of different heights of ti-base abutments on the color of anterior screw-retained zirconia restorations fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technologies may affect the optical clinical outcome. The purpose of this study was to measure and compare the color parameters of zirconia crowns in different shades on ti-base abutments. Identical specimens (N = 160) were milled to restore the screw-retained central maxillary incisor crown, using 5% mol yttria zirconia (5Y-TZP). The specimens were designed using computer design software to match 3.5 mm and 5.5-mm ti-base abutments and milled using one CAD-CAM technology. Specimens were divided into four main groups depending on zirconia shade (A1/0, A2/3, A3.5/4 and B2/3) and then assigned to two subgroups according to ti-base height. Color measurements in the CIELab coordinates were made using a spectrophotometer under room-light conditions. Color difference (ΔE*) values were calculated using the CIE76 and CIEDE2000 formula. Within the group of A0/1 and A2/3, for 5.5 mm abutment height, a significant difference was found between the means of colors ∆E00 and ∆Eab (p < 0.01). Using a 5.5 mm-height ti-base abutment may produce a clinically unacceptable outcome (ΔEab > 2) in A1/0 and A2/3 color groups.

7.
Materials (Basel) ; 15(14)2022 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-35888421

RESUMO

Background: The purpose of this study was to measure and compare the strain levels in the peri-implant bone as generated by the blade-like implant (BLI) and the screw-type implant (STI) with two different internal connections (hexagonal and conical) and with a 1:1 and 2:1 crown/implant (C/I) ratio. Methods: The implants (BLI and STI) were placed into sawbones according to the manufacturer's protocol. Two strain gauges, horizontal and vertical to the implant axis, were placed around each implant on the bone surface 1 mm from the cervical part. Each implant was loaded by a material testing machine at a force of 100 N. Micro-strains (µÎµ) generated in the surrounding bone were measured by a strain gauge and recorded. Results: Recorded micro-strains were not significant in both the insertion and loading phases (p < 0.0625). The average recorded micro-strain values were lower in the horizontal dimension of STI with hexagonal connection when the C/I ratio was 2:1 compared with BLI, 210 µÎµ and 443 µÎµ, respectively. Conclusion: Within the limitations of this study, implant design, implant-abutment connection and C/I ratio did not influence strain values in bone and there is no statistically significant effect of these parameters on bone.

8.
J Prosthodont ; 31(9): 771-777, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35061925

RESUMO

PURPOSE: To estimate the effects of the thermal cycling (TC) process on the metal surfaces of Locators, as well as retention loss, and the correlation between them. MATERIALS AND METHODS: Twenty-five new Locator R-Tx were included in the study. Four areas were marked on each Locators' patrix metal surface and scanned using a confocal scanner (µsurf explorer; NanoFocus). Three surface roughness parameters were measured in the scans: Sa (average distance of peaks from the central plain of the area), Vmp (volume of the peaks in the area), and Spc (mean curvature of the peaks describing the degree of their sharpness). Retention test was performed using Instron® 4500 compression tension tensile tester at a speed of 10 mm/min. The retention tests were done using a working model made of two acrylic blocks in which the Locator system parts were inserted. The surface parameters measurements and the retention tests were performed 2 times, once before and once after TC. The Locators were subjected to 15,000 TC cycles by investing them into 2 tubs with different water temperatures, 55°C and 5°C. During each 60-second cycle, the Locators were submerged in each tub for 20 seconds, with a 10 second transition time between the tubs. The post-TC retention and surface parameters measurements were compared with those prior to TC and the prior to TC measurements served as controls. Changes in parameters before and after TC were analyzed by a two-way ANOVA nested model with random intercept and slope by restricted maximum likelihood method. Correlation between retention and surface parameters was quantified and examined using Kendall's correlation test. The findings were considered statistically significant if p < 0.05. RESULTS: There was a significant decrease in retention of 16.6N at the second retention test (p < 0.001). A significant statistical decrease in surface parameters were measured after TC process, Sa and Vmp (18 ×10-3 µm, p = 0.041 and 0.94 ×10-3 1/µm, p = 0.001, respectively). A significant statistical increase in Spc of 6.4 ×10-3 µm3 /µm2 (p = 0.023) was noticed. The correlation between retention decreases and surface changes was not statistically significant. CONCLUSION: The TC process causes a substantial reduction in retention to the Locator system over time. In addition, TC causes significant but minor changes to the Locator surface area. Most of the changes are in the horizontal dimension.


Assuntos
Retenção de Dentadura , Revestimento de Dentadura , Retenção de Dentadura/métodos , Análise do Estresse Dentário , Fatores de Tempo , Água , Propriedades de Superfície , Teste de Materiais
10.
Am J Otolaryngol ; 42(4): 103065, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33894627

RESUMO

PURPOSE: To investigate the recovery of loss of smell and taste among recovered COVID-19 patients. MATERIALS AND METHODS: This cross-sectional follow-up study is a sequel to a study by Biadsee et al. Among the previous study population of 128 non-hospitalized patients, positive for COVID-19 by reverse transcription-polymerase chain reaction (RT-PCR), 97 patients participated in a survey designed for this study. Information and data regarding loss of smell and taste, rate of recovery, xerostomia, and additional symptoms; (Cough, Myalgia, Weakness, Rhinorrhea, Nasal congestion) were collected. RESULTS: A total of 43 men and 54 women were included. Mean age was 37.5 years (range 19-74). Mean follow-up was 229 days (range 191-253). Sixty-five patients reported gustatory dysfunction during the disease of which 61.5% reported full recovery, 38.5% partial recovery. Of 65 patients who reported olfactory impairment during the disease, 52% had full recovery and 48% reported partial recovery of olfactory function. Complete recovery of olfactory function was positively associated with full recovery of gustatory function (p = 0.01). Gender did not significantly affect the recovery of OD and GD (p = 0.45, p = 0.90, respectively). Patients who experienced olfactory dysfunction as an initial symptom had lower rates of olfactory complete recovery (p = 0.043). CONCLUSION: After a mean follow-up of 229 days, complete recovery of smell and taste functions occurred in 52% and 61.5%, respectively. However, dysfunction persisted in 48%-38.5% of patients.


Assuntos
COVID-19/complicações , Transtornos do Olfato/virologia , Distúrbios do Paladar/virologia , Adulto , Idoso , COVID-19/diagnóstico , COVID-19/terapia , Estudos Transversais , Feminino , Seguimentos , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Transtornos do Olfato/diagnóstico , Transtornos do Olfato/epidemiologia , Prevalência , Recuperação de Função Fisiológica , Inquéritos e Questionários , Distúrbios do Paladar/diagnóstico , Distúrbios do Paladar/epidemiologia , Fatores de Tempo , Adulto Jovem
11.
Otolaryngol Head Neck Surg ; 163(4): 722-728, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32539587

RESUMO

OBJECTIVE: The coronavirus disease 2019 (COVID-19) pandemic poses a threat to global health. Early diagnosis is an essential key to limit the outbreak of the virus. STUDY DESIGN: Case series, study conducted between March 25, 2020, and April 15, 2020. SETTING: Ambulatory, nonhospitalized patients who were quarantined in a designated hotel for COVID-19 patients and were recruited by an advertisement at the hotel. SUBJECTS AND METHODS: In total, 140 patients participated in a web-based questionnaire assessing initial symptoms of common viral diseases, olfactory and taste functions, xerostomia, and orofacial pain. RESULTS: A total of 58 men and 70 women participated. Initial symptoms were cough (59.4%), weakness (47.7%), myalgia (46.9%), fever (42.2%), headache (40.6%), impaired sense of smell (38.3%), impaired sense of taste (32.8%), sore throat (26.6%), runny nose (26.6%), and nasal congestion (22.7%). All symptoms were more frequent among women; however, only runny nose was statistically significant (P = .018). The most common combination of symptoms was cough and weakness (37.5%). A total of 25.8% reported olfactory and taste dysfunctions in the absence of other symptoms. In a comparison between the sexes, cough and runny nose were the most common combination in women (P = .018). A total of 38.3% of patients reported olfactory dysfunction as an initial symptom. Anosmia and facial pain were more common among women (P < .001 and P = .01, respectively), and 56% of patients reported xerostomia. CONCLUSION: A considerable number of patients presented with olfactory and oral disorders. Interestingly, women presented with a different cluster of symptoms than men, which may suggest a new clinical approach to diagnosing COVID-19 disease.


Assuntos
Betacoronavirus , Infecções por Coronavirus/complicações , Diagnóstico Precoce , Obstrução Nasal/etiologia , Transtornos do Olfato/etiologia , Pneumonia Viral/complicações , Olfato/fisiologia , Adolescente , Adulto , Idoso , COVID-19 , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obstrução Nasal/diagnóstico , Transtornos do Olfato/diagnóstico , Pandemias , Pneumonia Viral/diagnóstico , Pneumonia Viral/epidemiologia , Estudos Retrospectivos , SARS-CoV-2 , Adulto Jovem